Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Shenzhen Meraif Import And Export Co., Ltd.
Home ProductsSMT KIC thermal profiler

Industrial Kic Thermal Profiler Kic X5 7 Channel ±1.2c Accuracy Easy Use

Supplier response is excellent and packing condition is good and delivery made as per schedule. product is very good..

—— Dora

good service tracking product

—— Kittip

Shipped the product I expected. Will do more orders in the future.

—— john

I'm Online Chat Now

Industrial Kic Thermal Profiler Kic X5 7 Channel ±1.2c Accuracy Easy Use

Industrial Kic Thermal Profiler Kic X5 7 Channel ±1.2c Accuracy Easy Use
Industrial Kic Thermal Profiler Kic X5 7 Channel ±1.2c Accuracy Easy Use
video play

Large Image :  Industrial Kic Thermal Profiler Kic X5 7 Channel ±1.2c Accuracy Easy Use

Product Details:
Place of Origin: USA
Brand Name: KIC X5 profiler
Certification: CE
Model Number: KIC X5 profiler
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: KIC X5 profiler 6700-10000usd
Packaging Details: KIC X5 profiler packing with wooden case
Delivery Time: KIC X5 profiler within 15 days after payment
Payment Terms: TT,western union,paypal and so on
Supply Ability: 300 sets per month KIC X5 profiler
Usage: Industrial, reflow oven temeperature profile test
Theory: Temperature Recorder and Analytical instruments
Detailed Product Description
Brand Name:: KIC X5 Profiler Usage:: Industrial, Reflow Oven Temeperature Profile Test
Theory:: Temperature Recorder Accuracy:: ±0.5℃(Full Scale), ±0.5℃(Full Scale)
Temperature Range:: -150℃~1050℃ Resolution:: Variable 0.3C To 0.1C
Internal Operating Temp:: 0C To 105C Sample Rate:: 0.1 To 10 Per Second
Brand:: SMT Thermal Profiler Skype: Sensenhenhao
Whatsapp: +8613424013606 Wechat: JoyLY0322
Email: Joy@wickon.net
High Light:

thermal profiler equipment

,

reflow oven temperature profile

SMT thermal profiler KIC X5 7 channel, KIC X5 Profiler for SMT reflow oven

 

Intelligent Thermal Profiler

 

Robust Hardware – Ease of Use – Process Optimization
2 Year Warranty – 24 Hour Word Class Customer Support

 

KIC X5 thermal profiler Robust and Compact Hardware

 

This new and improved hardware is designed to withstand the roughest and toughest daily handling! The electronic circuitry is designed to tolerate a high level of voltage spikes that occasionally occur in some ovens and wave solder machines.

 

KIC is putting their money where their mouth is by offering a standard TWO YEAR warranty on this durable profiler.

 

The X5 is availalbe in 7, 9, and 12 channel versions using standard type K thermocouple connectors and uses standard AAA or recharageable batteries. Additionally you can power the X5 via the USB cable when connected to a computer. Get better data to precisely identify what is going on with each thermal profile and process in the factory.

 

KIC X5 thermal profiler Data Intelligence Software

 

The X5 software uses a modern, graphical interface that quickly and intuitively guides you through the task of profiling. Manual prediction capability comes standard with the X5, allowing you to manually adjust and improve upon your process or oven setup. The Navigator PowerTM software feature automates process improvements and optimization for you and ships standard with the X5Within seconds, the Navigator Power will identify the single best oven setup.

 

The X5 also comes standard with SPC charting software that helps reveal changes in the profile over time.

 

The X5 hardware and software establish a new generation of profiler to improve your production quality, productivity, and documentation.

 

KIC X5 thermal profiler Technical Specifications

 

1.Accuracy: ±1.2C


2.Resolution: Variable 0.3C to 0.1C

 

3.Internal Operating Temp: 0C to 85C


4.Thermocouple Compatibility: Type K, 6 channels


5.Temperature Range: -150C to 1050C


6.Power Requirements: Standard 9V alkaline battery

 

7. Data Points: 224,640


8.Dimensions: See Temperature Tolerance Chart below for specifications

 

9. Sample Rate: 0.1 to 10 per second

Datalogger Model: data is downloaded to the computer through a cable after the run.
Dual Unit Model:data is sent to the computer in real-time during the run. It is also stored internally for high-speed download after the run.

Computer Configuation

Minimum System Requirements

        1.When KIC 2000 Software is running on the same computer as the Oven software, and/or when additional KIC 2000 Software options are installed, a faster CPU and more RAM may be required.

        2.A USB to Serial Adapter may be required to connect the SlimKIC 2000 for profiling.

        3.Contact KIC for issues with operating systems other than those listed.

400 MHz Processor, Celeron / 128 Mb RAM1
1 Gb available storage (for product history)
Video 1024 x 768 resolution / 16-bit
1 available serial port or USB port2
1 available parallel port or USB port for software key options
soft® Windows® 2000 or XP3

 

KIC X5 thermal profiler picture show:

Industrial Kic Thermal Profiler Kic X5 7 Channel ±1.2c Accuracy Easy Use 0Industrial Kic Thermal Profiler Kic X5 7 Channel ±1.2c Accuracy Easy Use 1

 

Contact Details
Shenzhen Meraif Import And Export Co., Ltd.

Contact Person: Miss. JOY Liang

Tel: +8613424013606

Send your inquiry directly to us (0 / 3000)